Advantage Solar AC Series Inverters are the LatestDevelopped Solar&Wind and Grid Combination inverter by Multifit Company.TheBiggest Feature of this inverter is with the bypass solution between the GridPower Supply and battery bank charged by hybrid solutions like wind or PV. It is known as an Inverter with ATSfunction from the Solar or Wind Power to the Mains Power It is applying the automatic CPUControl,and the Energy Saving Funciton as a common property. Multifit Company is the only oneManufacturer of this new inverter (Solar AC series). Traditional Solar Inverter: they are usedon the stand Alone Solar Power Station or wind Power Station simply,when theEnergy Produced from the Solar Panel or Wind turbine is running out, or theBattery Bank is not charged fully,the Power Supply will be Cutted off, and thesystem is not going to supply any other energy.Our Solar AC Series new Invertersolved this problem absolutely. When the energy produced from the solar Panelor Wind turbine is not enougth, the Inverter will change to the Grid Power andcontinue to supply the power to AC Equipment and charge the battery at the sametime,the customer can used the power without any break down. Our Solar AC Inverterhad been widely used on the mountainous area and Inland,the area where have notenough power and less. Solar power or wind power primary or gridpower primary can be setted by customers ProductCharacteristic High Efficiency/Energy Saving Low self-Consumption below 1.2A.It canreach zero at energy saving mode. Make sure the load capacity is above200W.or the inverter can not be restarted automatically Leading energy saving technology With the AVR function.AC voltage fluctuatedis within +-5% Pure sine wave Extreme overload capacity and super loadcapacity WorkingAppliance:Air-conditioners.refrigerators.water pumps.TV.Light.fans and other householdappliances and office appliances etc. Durable. LF transformer technologydesign.it is suitable for the poor working conditions or where the grid poweris not stable DC reverse polarity protection PerformanceCharacteristic CPU Technology control Big Charging current. up to 70Amp. Intelligent LED display:Grid powe.battery.ACoutput.Fault.Saving.Low voltage.Charging. Charging curren.Battery capacity. Intelligent battery management for maximumbattery life Automatically switch between the grid andinverter mode Transfer time is below 4 ms if the gridpower are cutted off 220V/110V AC 50/60Hz is optional It can work with the generator Intelligent fan control mode.The fan workat Temperature ≥30℃.the inverter will protect byitself at temperature ≥100℃ LCDDisplay Data Input/Output voltage | Output Power | Battery Voltage | Charge current | Input Frequency | Charge current setting | Language Version:Chinese/English/French/Russian | Charging voltage setting | Battery Capacity setting | Battery type setting | Solar Prior Grid prior setting | Energy saving | CommunicationData Current | Rated power of load | Input/output voltage | Frequency | Battery capacity | Temperature | Remote control operation | Record of history data | TechnicalData SolarAC AC output Load | SolarAC 5000W | SolarAC 6000W | Nominal AC voltage Optional 220V/120V | 220V/200-240V 120V/105V-132V | 220V/200-240V 120V/105V-132V | Nominal AC frequency | 50Hz/60Hz | 50Hz/60Hz | Continuous AC power for 3 hours 25℃ | 5000W | 70000W | Continuous AC power 25℃ | 5000W | 6000W | Nominal AC current/ Max.AC current(peak) | 22.78A/68.18A 1ms 41.67A/125.00A 1ms | 27.28A/81.81 1ms 50A/150A 1ms | THD output voltage | ≤3% | ≤3% | Power Factor | 1.0 | 1.0 | AC input(generator or grid) | | | AC input voltage/range | 220V/165-270V 120V/105V-132V | 220V/165-270V 120V/105V-132V | AC input frequency | 50Hz/60Hz | 50Hz/60Hz | Battery DC input | | | Battery voltage/range Optional | 24V/20-32V 48V/40-64V | 48V/40-64V | Max.battery charging current/continuous charging current at 25℃ | 30A/10-30A | 30A/10-30A | Battery type/Battery Capacity | Lead acid 100-1000Ah | Lead acid 100-1000Ah | Charge control mode | Lead acid 100-1000Ah | Lead acid 100-1000Ah | Efficiency/Self-consumption | | | Max.efficiency | >90% | >90% | Self-consumption with no load | 45W | 50W | Self-consumption with no load /standby/for LCD type only | 5W | 5W | Full intellective protection | Over voltage/over charge/AC short circuit/overload/battery discharge voltage/battery over voltage/overtemperature/over current/overheat protection/ dc polarity label | Transfer time | ≤ 4ms | ≤ 4ms | Dimenstion(L×W×H) | 440×305×200 | 440×305×200 | Net Weight | 32 | 35 | Operating temperature range | -20℃ ~ 45℃ | -20℃ ~ 40℃ | Degree of protection according to IEC60529 | IP20 | IP20 | Noise emission typical | ≤30dB (1M) | ≤30dB (1M) | Permissible value for relative humidity | 0% ~ 95% | 0% ~ 95% | Accessories | | | DC terminal | Anderson connector | Anderson connector | AC terminal | Europe terminal | Europe terminal | Warranty | 2year | 2year | Certificate | CE/ISO9001 | CE/ISO9001 | Instruction Manual | yes | yes | Optional Function | | | Battery Cable | Optional | Optional | Interface USB/RS232 | Optional | Optional | SNMP Card | Optional | Optional | Software CD | Optional | Optional | Internet monitor | Optional | Optional | Remoted control | Optional | Optional | DC reverse polarity protection | Optional | Optional | Automatically restart after cut off | Optional | Optional | Split phase 220V/110V+-5%:output | Optional | Optional | Alarm at inverter mode/silence | Optional | Optional | LCD Display | Optional | Optional | Due to continuous innovation.research andproduct improvement.the specifications in this product information sheet aresubject ot change without prior notice.the specifications may deviate slightlyand are not guaranteed. The data do not refer to single module ofcontract and they are not part of the offer.they only serve for comparison todifferent module types |