AC output Load | VMI-D 3000W | VMI-D 4000W | VMI-D 5000W |
Nominal AC voltage Optional 220V/120V | 220V/200-240V 120V/105V-132V | 220V/200-240V 120V/105V-132V | 220V/200-240V 120V/105V-132V |
Nominal AC frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Continuous AC power for 3 hours 25℃ | 2700 W | 3600 W | 4500 W |
Continuous AC power 25℃ | 2400 W | 3200 W | 4000 W |
Nominal AC current/ Max.AC current(peak) | 10.91A/32.73A 1ms 20.0A/60.0A 1ms | 14.55A/43.63A 1ms 26.66A/80.0A 1ms | 18.19A/54.55A 1ms 33.33A/99.99A 1ms |
THD output voltage | ≤3% | ≤3% | ≤3% |
Power Factor | 0.8 | 0.8 | 0.8 |
AC input(generator or grid) | | | |
AC input voltage/range | 220V/165-270V 120V/105V-132V | 220V/165-270V 120V/105V-132V | 220V/165-270V 120V/105V-132V |
AC input frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Battery DC input | | | |
Battery voltage/range Optional | 12V/10-16V 24V/20-32V 48V/40-64V | 24V/20-32V 48V/40-64V | 24V/20-32V 48V/40-64V |
Max.battery charging current/continuous charging current at 25℃ | 30A/10-30A/50A | 30A/10-30A/50A | 30 A/10-30A/ 50 A |
Battery type/Battery Capacity | Lead acid 100-1000Ah | Lead acid 100-1000Ah | Lead acid 100-1000Ah |
Charge control mode | 3 stage | 3 stage | 3 stage |
Efficiency/Self-consumption | | | |
Max.efficiency | >85% | >85% | >85% |
Self-consumption with no load | 30W | 30W | 30W |
Self-consumption with no load /standby/for LCD type only | 5W | 5W | 6W |
Full intellective protection | Over voltage/over charge/AC short circuit/Over load/battery discharge voltage/battery over voltage/Over temperature/Over current/Over heat protection/ DC polarity label |
Transfer time | ≤ 4ms |
Dimenstion(L×W×H) | 540×250×196 mm | 540×250×196 mm | 540×250×196 mm |
Net Weight | 32 | 34 | 36 |
Operating temperature range | -20℃ ~ 45℃ | -20℃ ~ 40℃ | -20℃ ~ 45℃ |
Degree of protection according to IEC60529 | IP20 | IP20 | IP20 |
Noise emission typical | ≤30dB (1M) | ≤30dB (1M) | ≤30dB (1M) |
Permissible value for relative humidity | 0% ~ 95% | 0% ~ 95% | 0% ~ 95% |
Accessories | | | |
DC terminal | Anderson connector | Anderson connector | Anderson connector |
AC terminal | Europe terminal | Europe terminal | Europe terminal |
Warranty | 2 years | 2 years | 2 years |
Certificate | CE / ISO9001 | CE / ISO9001 | CE / ISO9001 |
Instruction Manual | yes | yes | yes |
Optional Function | | | |
Battery Cable | Optional | Optional | Optional |
Interface USB/RS232 | Optional | Optional | Optional |
SNMP Card | Optional | Optional | Optional |
Software CD | Optional | Optional | Optional |
Internet monitor | Optional | Optional | Optional |
Remoted control | Optional | Optional | Optional |
DC reverse polarity protection | Optional | Optional | Optional |
Automatically restart after cut off | Optional | Optional | Optional |
Split phase 220V/110V+-5%:output | Optional | Optional | Optional |
Alarm at inverter mode/silence | Optional | Optional | Optional |
LCD Display | Optional | Optional | Optional |